ISO pre-evaluation checklist for fire departments
Before an ISO survey, gather the records the field representative will ask to see: truck and hose tests, training by member, hydrant inspections and flow tests, and your written procedures. Here are 23 things to have ready, with a free two-page printout.
Last reviewed November 21, 2026
What should we do before the visit?
- Fill in the forms in the presurvey packet Verisk sends. The packet has a questionnaire on your fire suppression resources.
- Check the maps in the packet. They show your response area, your stations and the areas with hydrants as Verisk has them on record.
- Update the commercial building list, and mark every sprinklered building. Verisk needs to identify all of them.
- Pull sprinkler system test records, if you keep them. They help Verisk judge the sprinkler protection.
- Pick one person who knows the records to sit with the field representative. The interview covers tools, equipment, testing, hose, stations, response to alarms and training.
Which fire department records will ISO ask for? (50 points)
- Station addresses, and the equipment list for each truck. The representative reviews and verifies stations, apparatus and the equipment carried.
- Pumper performance test records. Verified only if the tests followed NFPA 1911.
- Hose test records. Verified only if the tests followed NFPA 1962.
- Aerial ladder and elevating platform test records, if you run one. Verified only if the tests followed NFPA 1911.
- Training records for every member, by training item. For maximum credit: company training 16 hours a member a month; training facility use 18 hours a year; officers 12 hours a year; new drivers 60 hours; existing drivers 12 hours; hazardous materials 6 hours a year; recruits 240 hours in the first year. No records, no credit.
- Pre-fire plan inspection records, with notes and sketches. For maximum credit, each commercial, industrial, institutional and similar building is inspected once a year.
- Records of how many members respond to structure fire alarms. Personnel is the largest item in the fire department section, 15 points, and is based on who is available to respond to first alarms.
- Written procedures for structure firefighting, and your incident management system. Operational considerations, 2 points.
Which water supply records count? (40 points)
- Hydrant inspection records. Verisk looks at how often hydrants are inspected and how complete the records are.
- Hydrant flow test records, none older than five years. Full credit needs tests every five years or less. Tests ten years old or older earn nothing.
- Your hydrant marking program, if you have one. Marking is part of the 7 points for inspection and flow testing.
- For areas without hydrants: how you supply water. Hauled water or a hose relay has to deliver 250 gpm within 5 minutes of the first truck arriving and hold it for 2 hours.
- Talk to the water utility before the visit. The credit is the same whether the department or the water provider does the hydrant work, so their records count too.
What about the 911 center? (10 points)
- Tell your 911 center the survey is coming. It is graded on emergency reporting (3 points), telecommunicators (4) and dispatch circuits (3). Those records are theirs, not yours.
- Ask the center for your dispatch history, if you want response times considered. Deployment can be judged from computer-aided dispatch history instead of distance from stations.
What earns the extra credit for community risk reduction? (5.5 points of extra credit)
- The fire prevention code your community has adopted, and who enforces it. Code adoption and enforcement, 2.2 points, including inspector qualifications and inspections.
- Your public fire safety education programs. 2.2 points: the programs, who teaches them and what was done.
- Fire investigation: who has the authority, who does it, and the records. 1.1 points.
What happens after the survey?
The representative meets briefly with community officials to go over what was collected. The results are not ready at that meeting. When the grading is done, the fire chief can ask Verisk for the report at no charge: how to find your ISO rating.
How WatchRoom handles this
WatchRoom builds the evaluation documents from the records the crew already keeps: training hours by category, structure fires with response counts, hydrants and flow tests, pre-plans and community risk, for whatever twelve-month window the evaluator asks about. The facts that do not change from year to year are entered once and carried onto every form. It shows an estimate of your class; the official grade is Verisk's. See the ISO pages or the prices.
Related guides
Questions chiefs ask
How do I prepare for an ISO evaluation?
Fill in the presurvey packet Verisk sends, then gather the records its field representative reviews: pumper, hose and aerial test records, training records for every member, hydrant inspection and flow test records, pre-fire plan inspections, and your written procedures.
What records does ISO look at?
For the fire department: stations, apparatus and the equipment carried, pumper performance tests, hose tests, aerial ladder tests, and training records. For water: hydrant inspections and flow tests. Verisk also grades the 911 center and gives extra credit for code enforcement, public education and fire investigation.
Does ISO accept any hose or pump test?
No. Verisk's fire department survey page says pumper and aerial test records are verified only if the tests followed NFPA 1911, and hose test records only if they followed NFPA 1962.
Do we get our score at the end of the visit?
No. Verisk says the results of the survey are not available at the closing meeting.
Sources
- ISO Mitigation: Preparing for the Survey: the presurvey packet and what to have on hand
- ISO Mitigation: Fire Department Survey: what the field representative reviews, and the test standards
- ISO Mitigation: Items Considered in the FSRS: the points for each item
- ISO Mitigation: Training: the training hours and the rule on records
- ISO Mitigation: Water Supply Evaluations: water supply figures
- ISO Mitigation: Fire hydrants in residential areas: flow test ages
- ISO Mitigation: The critical relationship between fire departments and water providers: credit for hydrant work done by the water provider
- ISO Mitigation: After the Survey: the closing meeting
Facts on this page were last checked against these sources on November 21, 2026. Rules change; the source is the authority.
Keep the records once, use them everywhere
WatchRoom keeps these records as the crew works, so the packet is a download, not a month of digging. The official class is always Verisk's.
More free guides
- Hydrant flow test calculatorPitot readings to gallons per minute, the flow at 20 psi, and the NFPA 291 color class. Free, in your browser.
- How the ISO rating worksThe 105.5 points, the class lines, the training hours ISO counts, and where volunteer departments lose points.
- How to find your ISO ratingThere is no public lookup. Who Verisk gives the class to, the number a chief calls, and the free report a department can ask for.
- ISO training hours: what countsThe eight training items ISO credits, the hours for maximum credit on each, and the records that prove them.
- NERIS reporting for small departmentsWhat replaced NFIRS, the dates, how a department gets set up, and the reasons a NERIS report gets sent back.
- Fire department grants: AFG and SAFERThe three FEMA fire grants, who can apply, what each pays for, and what to have ready before the window opens.
- NEMSIS for fire departmentsWhat NEMSIS is, how it differs from NERIS, and how a patient care report gets from the truck to the state.
- Switching fire department softwareWhat to get out of the old system, what to ask the new vendor, and the order to do it in. A checklist.
- Fire service glossaryISO, PPC, FSRS, NERIS, NEMSIS, AFG, SAFER and the rest of the paperwork alphabet, in plain words.
- 12-month drill calendarTwelve monthly themes and 36 drill ideas, with the ISO training item each relates to. A one-page printout.