Fire service glossary: the paperwork terms in plain words
24 terms a new chief or secretary runs into in the first year, each in a sentence or two. Where a term has its own guide, the link is beside it.
Last reviewed November 21, 2026
What do these fire service terms mean?
- AFG (Assistance to Firefighters Grant)
- FEMA's grant for equipping and training emergency personnel. Fire departments, nonaffiliated EMS organizations and state fire training academies apply directly. Fire department grants
- Automatic aid
- A standing agreement that a neighboring department is dispatched with yours on the first alarm, without anyone having to ask. Compare mutual aid.
- CAD (Computer-aided dispatch)
- The 911 center's system that records a call and sends units. Its times (dispatched, en route, on scene) are where an incident report's times come from.
- Combination department
- A department with both paid and volunteer firefighters.
- ePCR (Electronic patient care report)
- The medical record a crew writes for a patient. In the United States it follows the NEMSIS standard. NEMSIS for fire departments
- FP&S (Fire Prevention and Safety)
- FEMA's grant for fire prevention work and for research into firefighter health and safety. Fire department grants
- FSRS (Fire Suppression Rating Schedule)
- The schedule Verisk uses to grade a community's fire protection. It has 105.5 points: 50 for the fire department, 40 for water supply, 10 for emergency communications, and 5.5 of extra credit for community risk reduction. How the ISO rating works
- ISO (Insurance Services Office)
- The part of Verisk that grades community fire protection for insurers. An ISO rating is the common name for the PPC class it assigns. How the ISO rating works
- Mutual aid
- Help from a neighboring department when yours asks for it. Compare automatic aid.
- Needed fire flow (NFF)
- The water a building would need to fight a fire in it, in gallons per minute. Verisk figures it from the building's area, construction, occupancy and exposure; it runs from 500 to 12,000 gpm. The hydrant flow test calculator
- NEMSIS (National Emergency Medical Services Information System)
- The national standard and database for patient care reports, a program of NHTSA's Office of EMS. Agencies report to their state, and the state sends the national part on. NEMSIS for fire departments
- NERIS (National Emergency Response Information System)
- The national incident reporting system for fire departments, run by the U.S. Fire Administration. It replaced NFIRS; every incident from January 1, 2026 goes to NERIS. The NERIS guide
- NFIRS (National Fire Incident Reporting System)
- The national incident reporting system before NERIS. It shut down in February 2026. The NERIS guide
- NFPA (National Fire Protection Association)
- The body that publishes the fire service's consensus standards, each known by its number. NFPA 291, for one, covers hydrant flow testing and marking.
- Pitot pressure
- The pressure of the water stream leaving an open hydrant, read with a pitot gauge. It is the number a flow test turns into gallons per minute. The hydrant flow test calculator
- PPC (Public Protection Classification)
- The grade Verisk gives a community's fire protection, from Class 1 (the best) to Class 10. Insurers use it in setting property insurance prices. How the ISO rating works
- PPE (Personal protective equipment)
- Turnout coat and pants, helmet, hood, gloves and boots.
- Pre-plan (Pre-incident plan)
- What a crew writes down about a building before there is ever a call there: the layout, the hazards, the water, the utilities and who to call.
- Residual pressure
- The pressure left in the water main while a hydrant is flowing. Fire flow is rated at 20 psi residual. The hydrant flow test calculator
- SAFER (Staffing for Adequate Fire and Emergency Response)
- FEMA's grant for adding or keeping firefighters. One part pays for hiring; the other pays for recruiting and retaining volunteers. Fire department grants
- SCBA (Self-contained breathing apparatus)
- The air pack: a mask, a regulator and a cylinder of air on the firefighter's back.
- SOG (Standard operating guideline)
- A written guide to how the department handles a kind of job, leaving room for judgment on scene.
- SOP (Standard operating procedure)
- A written rule for how the department handles a kind of job.
- Static pressure
- The pressure in the water main with no hydrant flowing. The hydrant flow test calculator
How WatchRoom handles this
WatchRoom is records software for fire departments. It files incidents to NERIS, sends patient care reports to the state with the EMS add-on, sorts training into the ISO categories, and keeps the hydrant, truck and gear records a grading or a grant asks for. See everything it does or the prices.
Questions chiefs ask
What is the difference between ISO and PPC?
ISO is the organization (Insurance Services Office, part of Verisk). PPC, the Public Protection Classification, is the grade it gives a community, from Class 1 to Class 10. People say ISO rating and mean the PPC class.
What is the difference between NERIS and NFIRS?
NFIRS was the national fire incident reporting system. NERIS replaced it. Every incident from January 1, 2026 goes to NERIS, and NFIRS shut down in February 2026.
What is the difference between an SOP and an SOG?
A standard operating procedure is written as a rule to follow. A standard operating guideline is written as guidance that leaves room for judgment on scene. Departments use the two words for the same kind of document.
Sources
- ISO Mitigation: Fire Suppression Rating Schedule overview: the FSRS, its point split and the PPC classes
- ISO Mitigation: Water Supply Evaluations: needed fire flow and 20 psi residual
- U.S. Fire Administration: NFIRS Sunset: NERIS, NFIRS and the dates
- NEMSIS: What is NEMSIS: NEMSIS and who runs it
- U.S. Fire Administration: Assistance to Firefighters Grants programs: AFG, SAFER and FP&S
Facts on this page were last checked against these sources on November 21, 2026. Rules change; the source is the authority.
Keep the records once, use them everywhere
WatchRoom keeps the records behind most of these terms in one place. The demo opens with no sign-in.
More free guides
- Hydrant flow test calculatorPitot readings to gallons per minute, the flow at 20 psi, and the NFPA 291 color class. Free, in your browser.
- How the ISO rating worksThe 105.5 points, the class lines, the training hours ISO counts, and where volunteer departments lose points.
- How to find your ISO ratingThere is no public lookup. Who Verisk gives the class to, the number a chief calls, and the free report a department can ask for.
- ISO training hours: what countsThe eight training items ISO credits, the hours for maximum credit on each, and the records that prove them.
- NERIS reporting for small departmentsWhat replaced NFIRS, the dates, how a department gets set up, and the reasons a NERIS report gets sent back.
- Fire department grants: AFG and SAFERThe three FEMA fire grants, who can apply, what each pays for, and what to have ready before the window opens.
- NEMSIS for fire departmentsWhat NEMSIS is, how it differs from NERIS, and how a patient care report gets from the truck to the state.
- Switching fire department softwareWhat to get out of the old system, what to ask the new vendor, and the order to do it in. A checklist.
- ISO pre-evaluation checklistThe records to have ready before an ISO survey, section by section, with a free two-page printout.
- 12-month drill calendarTwelve monthly themes and 36 drill ideas, with the ISO training item each relates to. A one-page printout.